A 016/FAPC 016 - Oil Service Units

With the FA 016 hydraulic and lubricating systems can be filled or cleaned in off-line filtration
FAPC 016 with oil cleanliness monitor, the cleanliness class monitored permanently during the cleaning or filling process, the display area allows a choice of particle sizes: 4, 6, 14 and 21 micron, the display shows the classification number of the selected particle size, as specified by ISO 4406:1999)
Optional: trolley for easy transportation for FA 016 and FAPC 016
No tools are needed to open the housing and the filter element can be pulled out through the hang-in technique in the cover
On the bottom of the from inside to outside flown through filter elements there is a dirt retention valve. If the filter element is pulled out of the housing, the dirt retention 
valve will close. Sedimented dirt is removed from the housing with the filter element.
Longer service intervals and higher machine availability 
FA 016/FAPC 016
Hydraulic fluids Mineral oil and biodegradable fluids (other fluids on request)
Temperature range of fluids 0°C - +60°C
Length of hoses Suction hose NG20 x 1.8 m long with suction strainer 250 µm; Pressure hose NG20 x 2 m long – lance 0.20 m long
Ambient temperature range 0°C - +50°C
Operating and transportation position Upright and horizontal

 

Pump design Internal gear pump
Suction height maximal 1.5 m
Clogging indicator Manometer


FA 016-1100 FA 016-1300 FA 016-1110 FAPC016-2105
Nominal flow rate
16 l/min* 16 l/min* 19 l/min* 16 l/min*
Filter fineness
3EN2 ß3(C)=200 5EN2 ß5(C)=200 3EN2 ß3(C)=200 3EN2 ß3(C)=200
Dirt capacity Mi at Q
280 g 270 g 280 g 280 g
Operating voltage
1 ~ 230 V 1 ~ 230 V 1 ~ 110 V 1 ~ 230 V
Operating frequency
50/60 Hz 50/60 HZ 60 Hz 50/60 HZ
Motor power
0,45 kW* 0,45 kW* 0,3 kW* 0,45 kW*
Viscosity: continuous operation min.
15 mm²/s 15 mm²/s 15 mm²/s 15 mm²/s
Viscosity: continuous operation max.
250 mm²/s 250 mm²/s 200 mm²/s 150 mm²/s
Viscosity: short-term operation max. 
400 mm²/s 400 mm²/s 400 mm²/s 150 mm²/s
Operating pressure max.
4 bar 4 bar 4 bar 4 bar
Weight
18,9 kg 18,9 kg 18,9 kg 24 kg
Particle monitor
- - - OPComII
Replacement element
V 7.1220-113 V 7.1220-13 V 7.1220-113 V 7.1220-113
*Indications at 50 Hz.